Biology, Electronics, Geology, Instrumentation, Subatomic particles

Carbon-14 for dating (Part 2)

In this part, are explained the methods to measure the quantity of carbon-14 in organic material, allowing to determine a fossil’s age.

The button below access the first part about carbon-14.

Carbon-14 (Part 1)Click here

Preparing the sample

In all methods, you must clean the sample manually, do chemical treatment, and transform it into carbon dioxide. 

Chemical treatment

For coal and organic remains, it’s used the AAA (acid-alkali-acid) method, which takes many hours. In AAA, the sample is washed with hydrochloric acid (HCl) at 80°C (176ºF) for 24 hours, filtered, and rinsed in distilled water. Then, washed with sodium hydroxide (NaOH) at 80°C for 24 hours, filtered and rinsed with distilled water again and you must wash with HCl for 24 hours, filter, rinse and dry.

Carbonates like shells, limestone, and speleothems, are cleaned and the external part is dissolved with a weak acid. Because the external part may receive foreign carbon, causing errors in dating. To extract bones’ collagen, it’s applied modified Longin’s method.

Converting in carbon dioxide

After the chemical treatment, the sample goes to a quartz tube with copper oxide (CuO) and silver, at temperatures between 900ºC (1652°F) and 1000°C (1832ºF). The CuO is to obtain an oxygen source and the silver serves for isolating sulfur and halogens.

All air must be removed from the tube by a vacuum line.

Carbon dioxide purification

The sample’s combustion produces steam, the later is frozen to separate from CO_{2}. The gas also passes through filtering by silver wool and oxidation with CuO, between 400ºC (752ºF) and 500ºC (932ºF). After purification, carbon dioxide is stored in a sealed glass tube.

Vacuum lines
Vacuum lines for combustion and purification of carbon dioxide. Source: Poznan Radiocarbon Laboratory.

Gas Proportional Counting (GPC)

This method counts the beta particles emitted by carbon-14 decay. After the CO_{2} purification, it’s put inside a conductor tube, where there is a conductor wire that receives high voltage. An insulating material must be between the wire (anode) and the cylinder (cathode).

GPC to measure carbon-14
The counter detects the voltage drop in R, counts the peaks, and has a signal amplifier. Source: Stanford.

This method uses the ionization principle. When a carbon-14 atom decays, beta particle is attracted by anode due to an electric field created by high voltage. Creating an ionization avalanche, producing many free electrons that will be attracted by the central wire. Accumulated electrons in the central wire go to R resistor and the electronic counter measures the voltage drop.

Liquid Scintillation Counter (LSC)

This method was popular in the 1960s. The CO_{2} reacts with melted lithium at 600ºC (1112ºF), forming the following reaction.

2CO_{2}+12Li\rightarrow Li_{4}C_{2}+4Li_{2}O

Adding distilled water.

Li_{4}C_{2}+4H_{2}O\rightarrow C_{2}H_{2}+4LiOH+H_{2}

Then, the acetylene (C_{2}H_{2}) passes through a catalyst column based on vanadium to become benzene (C_{6}H_{6}).

benzene
Benzene representation. Source: Toda Matéria.

The scintillator substance butyl PBD is added to benzene. The butyl PBD produces a flash when detects a beta particle. Light particles are detected by photomultipliers and their signals are analyzed by computer, determining the age of organic material. 

liquid scintillator counter
This is an example of scintillator counter, which will have a dedicated post. Source: GMI.

Accelerator Mass Spectrometry (AMS)

It’s considered the most efficient method, because samples can be smaller. Instead of count beta emittions, counts the quantity of carbon-14 in relation with carbon-12. 

Graphitization

The CO_{2} must be converted in graphite. In the first stage of graphitization, a small quantity of iron powder is preheated at 90ºC (194ºF). Then, this iron passes through oxidation and reduction processes to increase its catalytic properties. 

graphitisation to measure carbon-14
Equipment for graphitisation process. Source: GADAM Centre.

The CO_{2} is in a quartz tube with vacuum, it’s mixed with hydrogen gas to form the following chemical reactions with a temperature between 600ºC (1112ºF) and 630ºC (1166ºF). 

CO_{2}+H_{2}\leftrightarrow H_{2}O+CO

CO+H_{2}\leftrightarrow H_{2}O+C

The reactions above are made with preheated iron powder, which serves as a catalyst. The graphite is deposited in the iron and pressed before being analyzed.

Identifying carbon-14 quantity

AMS machine for carbon-14
AMS machine. Source: National Electrostatics Corp..
sample wheel for carbon-14
The sample is put in this central wheel to be analyzed in AMS. Source: Radiocarbon.

In one of the machine’s extremities, there are ion sources, which ionize carbon atoms with a cesium beam. Carbon atoms gain an extra electron and are accelerated by magnets and electrostatic devices. The injection magnet takes the graphite to Pelletron Accelerator. Where it is applied between 3 and 5 Megavolts in the positive pole to take electrons from carbon atom, making it a positive ion.

AMS machine to measure carbon-14
Source: intechopen.

Due to very high voltage, the pelletron accelerator is internally covered by sulfur hexafluoride (SF_{6}), an electric insulator. After the conversion to positive ion, the sample goes to analyzing magnet, which turns the beam 90º. It is in this part where carbon isotopes are separated. The lightest atom, in this case, carbon-12, is the one that bends more.

For being the heaviest isotope, carbon-14 is the only one that reaches the heavy ion detector, where collides with isobutane gas (C_{4}H_{10}). The energy generated is measured and carbon-14 atoms can be counted.

The main disadvantage of AMS method is high cost. Due to sample size, greater care must be taken to avoid contamination.

About Pedro Ney Stroski

Leave a Reply

Your email address will not be published. Required fields are marked *